Proven BAUER compressor units up to 85 bar – the durable series in horizontal format for demanding customers
Technical Data
Type designation |
Effective free air delivery ¹ |
Max. operating pressure ² |
Number of compressor stages |
Speed approx. |
Motor output |
Power consumption ¹ |
Net weight approx. | ||||
---|---|---|---|---|---|---|---|---|---|---|---|
l/min | m³/h | cfm | bar | psig | rpm | kW | kW | kg | lbs | ||
E 22.5-15 | 850 | 51 | 30 | 85 | 1230 | 3 | 1150 | 15 | 14 | 460 | 1010 |
E 23.4-22 | 1280 | 77 | 45 | 85 | 1230 | 3 | 920 | 22 | 20 | 670 | 1470 |
E 23.4-30 | 1700 | 102 | 60 | 85 | 1230 | 3 | 1200 | 30 | 27 | 735 | 1620 |
E 25.4-37 | 2000 | 120 | 71 | 85 | 1230 | 3 | 940 | 37 | 33 | 1430 | 3150 |
E 25.4-45 | 2600 | 156 | 92 | 85 | 1230 | 3 | 1200 | 45 | 42 | 1460 | 3210 |
E 28.2-55 | 3300 | 198 | 120 | 85 | 1230 | 3 | 1050 | 55 | 53 | 1500 | 3300 |
¹ Free air delivery according to ISO 1217, power consumption at maximum final pressure under certain conditions. Other ambient conditions result in different performance data. Values valid for 50 Hz.
² Max. operating pressure = max. safety valve pressure setting; reduced switch-off pressure.